Testing of electric motors and generators
Modern test bays
Computer based test sytsems for motors and generators 50Hz and 60Hz for load and no load test
DC Direct current supply up to 800V and 2500A,
Continuously adjustable rotary current supply 11 KV
Acceptance test for the repair of equipment for hazardous areas EEx e, EEx d, EEx p. EEx i for zone I and zone II
load generators up to 1000kW (up to 3000 rpm)
Tan delta measurements on high-voltage windings
partial discharge measurements for high-voltage windings
Vibration analyses and FFT analyses
Bearing analyses
Mobile test equipment for on site measurements
Iron loss measurements, including thermographic assessment
Recalculation and calculation of machines